{"product_id":"nidek-medical-nuvo-10-oxygen-concentrator-10l","title":"Nidek Medical Nuvo 10 Oxygen Concentrator (10L)","description":"\u003cp\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eThis item requires an Rx or Professional License\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eNidek Medical Nuvo 10 Oxygen Concentrator (Model 595)\u003c\/b\u003e is the flagship high-capacity stationary oxygen delivery system in the Nidek lineup, engineered for high-flow respiratory therapy requiring up to 10 Liters Per Minute (LPM) of continuous medical-grade oxygen. Designed to handle the rigorous demands of around-the-clock home and clinical therapy, this high-output workhorse eliminates the need for compounding dual 5L units. It features a heavy-duty, commercial-grade compressor block and optimized molecular sieve beds that quickly strip nitrogen from ambient air, reaching full therapeutic purity levels within minutes of activation. Pushing a powerful \u003cb\u003e15 PSI\u003c\/b\u003e of outlet pressure, the Nuvo 10 easily drives extra-long oxygen tubing configurations or powers specialized high-flow accessories like nebulizers and large-volume humidifiers without experiencing a drop in line pressure. Model 595 comes factory-equipped with Nidek's integrated \u003cb\u003eOxygen Concentration Status Indicator (OCSI)\u003c\/b\u003e sensor, which continuously analyzes output gas quality in real time.\u003c\/p\u003e\n\u003ch3\u003eDesign \u0026amp; Functional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum 10 LPM Continuous Output:\u003c\/b\u003e Delivers a reliable, high-volume flow scope ranging smoothly from 2.0 to 10.0 LPM to meet intensive clinical prescription profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLockable Flow Management Knob:\u003c\/b\u003e The variable flowmeter features a robust control knob that can be physically locked into a single prescribed tier with an Allen wrench, preventing accidental or unauthorized manipulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRapid Pressure Swing Absorption (RPSA):\u003c\/b\u003e Utilizes Nidek's advanced low-maintenance rotary poppet valve infrastructure to ensure stable, highly efficient oxygen extraction from ambient air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHeavy-Duty Mobile Cabinet:\u003c\/b\u003e Formed from a high-impact composite shell equipped with a rigid top handle, a rear storage pouch for extra tubing, and durable casters for effortless room-to-room transitions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications \u0026amp; Identification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand \/ Master Vendor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNidek Medical Products, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel Number \/ SKU\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e595 (Nuvo 10 High-Flow with OCSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eUPC \/ GTIN\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e038214001445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHCPCS Billing Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eE0424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDelivery Mechanism\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous Flow Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFlow Setting Scope\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 to 10.0 Liters Per Minute (LPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOxygen Output Concentration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e90% (+5% \/ -3%) at full 10 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutlet Pressure Level\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e15.0 PSI (1.03 BAR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Drive Configuration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e115V AC \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAverage Power Consumption\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNet Hardware Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e54.5 lbs (24.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePhysical Dimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e15.6\" W x 15.5\" D x 27.8\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCountry of Manufacture\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in the United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCompliance \u0026amp; Tax Tier\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eFDA Registered \/ FSA \u0026amp; HSA Eligible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eImportant Product Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIntelligent Multi-Point Diagnostics:\u003c\/b\u003e Backed by an internal 9V battery system that instantly triggers loud audible and visible LED alarms for power cuts, low oxygen concentration, high system pressure, or internal thermal overloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTool-Free Rear Access Hatch:\u003c\/b\u003e Simplifies routine maintenance by positioning the primary compressor intake filter and the mechanical running-hour tracking screen behind an easily accessible back panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eApplication Notice:\u003c\/b\u003e The Nuvo 10 is a high-capacity Class II prescription medical device. It must be operated and configured according to the exact prescription parameters provided by a licensed physician and is not built as a primary standalone life-support system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQ)\u003c\/h2\u003e\n\u003ch3\u003eWhat is the structural difference between the Nuvo 8 (Model 585) and the Nuvo 10 (Model 595)?\u003c\/h3\u003e\n\u003cp\u003eWhile both models utilize the same heavy-duty outer cabinet shell and weigh nearly the same (roughly 54 lbs), their internal processing capacities differ. The Nuvo 8 is calibrated to max out at 8 LPM with a 17 PSI line pressure, whereas the Nuvo 10 features larger internal molecular sieve volumes and an expanded compressor layout designed to deliver a full 10 LPM flow rate at a steady 15 PSI line pressure.\u003c\/p\u003e\n\u003ch3\u003eHow does the built-in OCSI sensor function to protect the user?\u003c\/h3\u003e\n\u003cp\u003eOCSI stands for \u003cb\u003eOxygen Concentration Status Indicator\u003c\/b\u003e. This factory-installed safety sensor continuously monitors the active chemical purity of the oxygen being produced by the sieve beds. If the purity level drops below safe therapeutic thresholds, the front interface will instantly switch from a solid green light to a flashing visual alarm accompanied by an audible warning tone.\u003c\/p\u003e\n\u003ch3\u003eHow often do the equipment filters need to be serviced?\u003c\/h3\u003e\n\u003cp\u003eThe black foam cabinet filter on the exterior should be pulled out and washed with mild dish soap and warm water once a week, then allowed to air-dry completely before reinsertion. The internal compressor intake filter behind the rear hatch should be completely replaced every 12 months.\u003c\/p\u003e\n\u003ch3\u003eCan I plug this unit into a standard household surge protector or power strip?\u003c\/h3\u003e\n\u003cp\u003eNo. Because the Nuvo 10 draws a continuous 600 Watts, it should always be plugged directly into a dedicated standard wall outlet. Running high-wattage medical machinery through consumer power strips or lightweight extension cords can cause significant voltage drops, which will trip the unit's onboard circuit breaker or cause the compressor to overheat.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eCompliance Standard:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003eFDA Class II Medical Device Regulations (21 CFR Part 807)\u003c\/h3\u003e\n\u003cp\u003eTo ensure strict compliance with current FDA regulations, EnhDme enforces a rigorous prescription verification policy for specific restricted medical devices. Because federal law restricts these devices to sale by or on the order of a licensed healthcare provider, orders containing prescription-regulated equipment will remain on a compliance hold and will not be dispensed until a valid prescription is successfully received and verified by our compliance team.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/enhdme.com\/pages\/prescription-rx-item-verification-policy\"\u003eLink to our prescription policy and contact information.\u003c\/a\u003e\u003c\/p\u003e","brand":"Nidek Medical","offers":[{"title":"Default Title","offer_id":45097653829747,"sku":"595","price":1452.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0656\/8866\/6227\/files\/nuvo-10_jpg.webp?v=1781304910","url":"https:\/\/enhdme.com\/products\/nidek-medical-nuvo-10-oxygen-concentrator-10l","provider":"EnhDme","version":"1.0","type":"link"}